Deka Surgery Laser Systems

By exploiting the characteristics of light-tissue interaction, surgery performed using laser is always at the forefront with regard to mini-invasiveness. In fact, the light absorption curves of the substances making up living tissue differ depending on the laser wavelengths, just as the effects these produce differ in the tissues themselves.

Laser surgery, which is noble and distinctive surgery, is becoming increasingly more recognised and appreciated by physicians and patients alike.

APPLICATIONS :-

  • ENT
  • Gynecology
  • Urology
  • General Surgery & Oncology
  • Neurosurgery
  • Endovascular Treatments




REQUEST CALLBACK
Ask Latest Price

Product Price: Get Latest Price

Product Details:
ApplicationENT Surgery
ModelC60 and C60H
Wavelength10.6 Um
Laser TypeCO 2 RF - PSD
Emission BeamTEM
Delay Emission TimeFrom 0.3 to 5 sec.
Beam Delivery7 Mirrors Articulated Arm with Counterweight.
HP PowerFrom 0.1 to 8 W
UP PowerFrom 0.5 to 60 W
CW Power30 W
Control PanelWide LCD Colour Touch Screen (10.4 Inch)
Electrical RequirementsFrom 100 to 120 Vac - 50/60 Hz, From 220 to 230 Vac - 50 Hz - 1,600 VA
Dimensions162 (H) x 59 (W) x 56 (D) cm, 192 (H) x 59 (W) x 56 (D) cm
Weight95 kg for C60 and C80, 100 kg for C60H and C80H
Emission ModesCW - SP - DP - HP - UP
SP PowerFrom 0.1 to 15 W
DP PowerFrom 0.2 to 15 W
Emission TimeFrom 0.01 to 0.9 sec.
The SmartXide2 Revolution: Absolute Precision and Control for the Most Advanced Microsurgery: The use of CO2 has considerably improved the performance of ENT microsurgery. Today CO2 laser is universally recognized as the gold standard for noninvasive ear, nose and throat applications.

DEKA, a world leader in the development of high tech laser systems, concentrated over thirty years of expertise into the technological excellence of SmartXide2.

The synergistic interaction of SmartXide2:
  • CO2 RF laser source with PSD® (Pulse Shape Design) technology,
  • High precision robotic scanning system (HiScan Surgical),
  • Micromanipulator with exclusive Hybrid technology.

Provides unparalleled performance of ENT applications.
In line with its ongoing commitment to innovation, DEKA paved the way for a new, multidisciplinary, avant-garde laser system: the SmartXide2 now featuring a diode laser module with power up to 50W. This modularity makes it the only worldwide CO2 laser platform.


Applications :

  • ENT Microsurgery
  • General Surgery

Sources :
  • CO2 - 10600nm
  • Diode CW/PW - 980nm
  • Radio Frequency
Yes! I am Interested
View PDF
REQUEST CALLBACK
Ask Latest Price

Product Price: Get Latest Price

Product Details:
UsageHospital
ApplicationENT Surgery
Laser TypeCO 2
Wavelength10.6 um
Emission ModeCW - PW - SP
Peak Power320 / 400 W
Repetition RateFrom 5 to 100 Hz
Pulse DurationFrom 0.2 to 80 ms
Beam DeliveryArticulated Arm with 7 Mirrors and Counterweight
Aiming BeamDiode Laser 5 mW 635 nm
Electrical Requirements230 Vac / 1.8 A (50-60 Hz)
Dimensions144/160 cm (H) x 48 cm (W) x 55 cm (D)
Weight38/43 kg
Maximum Scanning Area6.3 mm (400 mm EFL)
Dwell TimeFrom 200 us to 300 ms
Ablation DepthFrom 100 um to 2 mm (Selectable for Every Single Scanning Passage)
Scanning ModesPower Mode, Depth Mode
Focal LengthFrom 200 mm to 400 mm
Maximum Power CW30 / 50 W
Maximum Power SP15 / 25 W
Spot SizesMin. 140 um (200 mm EFL), Max. 4,5 mm (400 mm EFL)
Operative FieldMin 20 x 18 mm - Max 55 x 40 mm

Smartxide HS: Power, Precision, and Automation: The use of the CO2 laser has greatly enhanced operating methods in the field of ENT microsurgery and colposcopic gynecological surgery. The mini-invasive CO2 laser surgery, backed by advanced technologies, offers significant advantages over traditional techniques. The professional expertise of the surgeon, combined with innovative and robotized systems such as SmartXide HS, guarantees excellent results while reducing hospitalization and enhancing patient comfort.

A world leader in technological excellence, DEKA has designed SmartXide HS in line with criteria of simplicity, practicality, and mini-invasiveness. SmartXide HS: micrometrical precision guaranteeing microsurgical excellence.


Applications :

  • Laryngeal Microsurgery
  • Oral Surgery
  • Pharyngeal Surgery
  • Nasal Surgery
  • Tracheobronchial Surgery
  • Stapedotomy
  • Colposcopic Surgery

Sources :
  • CO2 - 10600nm
Yes! I am Interested
View PDF
REQUEST CALLBACK
Ask Latest Price

Product Price: Get Latest Price

Product Details:
ApplicationGynaecology
Wavelength10.6 um
Laser TypeCO 2 RF - PSD
Frequency50/60 Hz
Voltage100 to 120 V, 220-230 V
Emission BeamTEM
Beam Delivery7 Mirrors Articulated Arm with Counterweight
Control PanelWide LCD Colour Touch Screen (10.4 Inch)
Dimensions162 (H) x 59 (W) x 56 (D) cm, 92 (H) x 59 (W) x 56 (D) cm
Weight95 kg for C60 and C80, 100 kg for C60H and C80H
Emission ModesCW - SP - DP - HP -UP
SP PowerFrom 0.1 to 15 W
DP PowerFrom 0.2 to 15 W
Emission TimeFrom 0.01 to 0.9 s
Delay Emission TimeFrom 0.3 to 5 s
The SmartXide2 Revolution: Absolute Precision and Control for the Most Advanced Gynaecological Surgery: The use of CO2 laser has considerably improved the performance of gynecological surgery with totally mini-invasive operations. Today CO2 laser is universally recognized as the gold standard in numerous gynecological applications.

DEKA, the world leader in the development of high tech laser systems, concentrated over thirty years of expertise into the technological excellence of SmartXide2.

The synergistic interaction of SmartXide2:

  • CO2 RF laser source with PSD® (Pulse Shape Design) technology,
  • High precision scanning systems (HiScan Surgical and EndoScan),
  • Micromanipulator with exclusive Hybrid technology.

Provides unparalleled performance of gynecological applications.
In line with the ongoing commitment to innovation, DEKA paved the way for a new multidisciplinary, avant-garde laser system. SmartXide2 can operate in both the colposcopic and endoscopic fields, with a versatility that makes it the most advanced worldwide CO2 laser system.


Applications:

  • Colposcopy
  • Gynaecological Laparoscopy

Sources :
  • CO2 - 10600nm
  • Diode CW/PW - 980nm
  • Radio Frequency
Yes! I am Interested
View PDF
Save time! Get the Best Deal

*Your information is safe with us.

REQUEST CALLBACK
Ask Latest Price

Product Price: Get Latest Price

Product Details:
ApplicationDiagnostic Surgery
Laser TypeCO 2 RF - PSD
Frequency50/60 Hz
Voltage100-120 V, 220-230 V
Emission BeamTEM
Beam Delivery7 Mirrors Articulated Arm with Counterweight
HP PowerFrom 0.1 to 8 W
UP PowerFrom 0.5 to 60 W
Dwell TimeFrom 100 to 1000 us Circle - 350 us Clover
Scanning ShapesCut Mode Point, Circle, Clover
Control PanelWide LCD Color Touch Screen (10.4 Inch)
Dimensions162 (H) x 59 (W) x 56 (D) cm, 192 (H) x 59 (W) x 56 (D) cm
Weight95 kg for C60 and C80, 100 kg for C60H and C80H
Emission ModesCW - SP - DP - HP - UP
SP PowerFrom 0.1 to 15 W
DP PowerFrom 0.2 to 15 W
Emission TimeFrom 0.01 to 0.9 s
Delay Emission TimeFrom 0.3 to 5 s

Deka Revolution For Advanced Wound Healing And Car: Chronic wound care has become a top-priority issue for health systems worldwide. The expenditure for wound management has been rising in last years and will experience further growth, due to progressive ageing of population. It is estimated that about 7 million patients are affected by chronic wounds in U.S.A. alone, where US$25 billion dollars are spent annually. The continuous DEKA’s innovation research has revolutionized the field of chronic wounds management thanks to SmartXide2surgical CO2 laser.

SmartXide2 offers a great adjunctive treatment approach in wound therapy, particularly in difficult-to-heal cutaneous wounds, allowing clinicians to achieve unexpected results in wound closures as never before.


Applications :

  • Diabetic foot ulcers
  • Venous leg ulcers
  • Pressure ulcers
  • Wound dehiscence


Sources :

  • CO2 - 10600nm
Yes! I am Interested
View PDF
X
 

Download Brochure
Explore more products
Dynotech Instruments Private Limited

Koshy Mathew(Manager Sales)
803-804, Vishwa Sadan, District Center
Janakpuri, Delhi - 110058
India
Send Email
© Dynotech Instruments Private Limited. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited